OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XVD-ABCD1 AC100-240 datasheet PDF catalog K3HB-XVD-ABCD1 AC100-240 PDF datasheet

OMRON K3HB-XVD-ABCD1 AC100-240 datasheet PDF catalog K3HB-XVD-ABCD1 AC100-240 PDF datasheet

Brand: OMRON
Product model: K3HB-XVD-ABCD1 AC100-240
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-XVD-ABCD1 AC100-240 PDF datasheet K3HB-XVD-ABCD1 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
6 measurement methods, including 2Type of input: AC current input K3HB-XVD-ABCD1 AC100-240 PDF datasheet.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-XVD-ABCD1 AC100-240 PDF datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm. Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operationn K3HB-XVD-ABCD1 AC100-240 datasheet PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVD-ABCD1 AC100-240 datasheet PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PPB-CPAC11 AC100-240
OMRON Time interval table K3HB-PPB-CPAC11 AC100-240
Input type: PNP input type. Event input term
OMRON
Voltage and current panel meter
K3HB-XVD-A-DRT1 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-A-DRT1 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XAA-L1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L1AT11 AC100-240
Type of input: AC current input. Output type