Type of input: AC voltage input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-VLC-L1ET11 AC/DC24 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-VLC-L1ET11 AC/DC24
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DevicePower supply voltage: 100 to 240 VAC K3HB-VLC-L1ET11 AC/DC24 PDF datasheet.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-VLC-L1ET11 AC/DC24 PDF datasheet.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially availablle CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-VLC-L1ET11 AC/DC24 datasheet PDF catalog.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SSPDT output contacts, 5 A at 250 VAC (resistive load) K3HB-VLC-L1ET11 AC/DC24 datasheet PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.