Functions: Phase sequence and phase loss monitoring.
Rated input voltage: 200 to 500 VAC.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Fixed phase Asymmetry monitoring.
Prevents reverse motor rotation due to incorrect wiring.
Distinguishes between positive phases, reversed phases, and phase,
loss when power is turned ON K3HB-VLC-FLK1BT11 AC/DC24V PDF datasheet
K3HB-VLC-FLK1BT11 AC/DC24V
Voltage detection method enables application for any load current.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator. Models: OCR-H (51).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular K3HB-VLC-FLK1BT11 AC/DC24V PDF datasheet.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system K3HB-VLC-FLK1BT11 AC/DC24V PDF datasheet.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring. Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 0.25 to 0.5 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heateer el,
ement among several heater elements has been burned out K3HB-VLC-FLK1BT11 AC/DC24V datasheet PDF catalog.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-VLC-FLK1BT11 AC/DC24V datasheet PDF catalog.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.