OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-RPB-L2AT11 AC/DC24V datasheet PDF catalog K3HB-RPB-L2AT11 AC/DC24V PDF datasheet

OMRON K3HB-RPB-L2AT11 AC/DC24V datasheet PDF catalog K3HB-RPB-L2AT11 AC/DC24V PDF datasheet

Brand: OMRON
Product model: K3HB-RPB-L2AT11 AC/DC24V
Name: Rotating pulse meter
Sort: PDF datasheet
File language: English
File size: 1.48MB
Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model K3HB-RPB-L2AT11 AC/DC24V PDF datasheet K3HB-RPB-L2AT11 AC/DC24V )
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function K3HB-RPB-L2AT11 AC/DC24V PDF datasheet.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power K3HB-RPB-L2AT11 AC/DC24V PDF datasheet.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 3 transistor outputs (NPN open collector);
Data transmission output, DC current (0 to 220 mA, 4 to 20 mA) K3HB-RPB-L2AT11 AC/DC24V datasheet PDF catalog.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red K3HB-RPB-L2AT11 AC/DC24V datasheet PDF catalog.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66).
Related products
OMRON
Rotating pulse meter
K3HB-RNB-FLK3AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-FLK3AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PPB-L1AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-L1AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Load sensor, mV instrument
K3HB-VLC-BT11 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-BT11 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-L2BT11 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-L2BT11 AC/DC24V
Category: external supply 100mA DC10V. Input