OMRON K3HB-PPB-L2AT11 AC100-240 datasheet PDF catalog K3HB-PPB-L2AT11 AC100-240 PDF datasheet

Brand: OMRON
Product model: K3HB-PPB-L2AT11 AC100-240
Name: Time interval table
Sort: PDF datasheet
File language: English
File size: 1.59MB
Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-PPB-L2AT11 AC100-240 PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-PPB-L2AT11 AC100-240
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PPB-L2AT11 AC100-240 PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment K3HB-PPB-L2AT11 AC100-240 PDF datasheet.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic controol K3HB-PPB-L2AT11 AC100-240 datasheet PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-PPB-L2AT11 AC100-240 datasheet PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-L1BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-L1BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK1ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-FLK1ET11 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Voltage and current panel meter
K3HB-XVA-T11 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-T11 AC100-240
Type of input: AC voltage input. Output type