OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-CNB-A-DRT1 AC/DC24V datasheet PDF catalog K3HB-CNB-A-DRT1 AC/DC24V PDF datasheet

OMRON K3HB-CNB-A-DRT1 AC/DC24V datasheet PDF catalog K3HB-CNB-A-DRT1 AC/DC24V PDF datasheet

Brand: OMRON
Product model: K3HB-CNB-A-DRT1 AC/DC24V
Name: Cumulative / increase / decrease pulse meter
Sort: PDF datasheet
File language: English
File size: 1.34MB
Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs(SPST-NO);
Data transmission output, None.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse K3HB-CNB-A-DRT1 AC/DC24V PDF datasheet.
Two display colors (switchable): green/red K3HB-CNB-A-DRT1 AC/DC24V
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) K3HB-CNB-A-DRT1 AC/DC24V PDF datasheet.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-CNB-A-DRT1 AC/DC24V PDF datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operatioon K3HB-CNB-A-DRT1 AC/DC24V datasheet PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-CNB-A-DRT1 AC/DC24V datasheet PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PNB-A-DRT1 AC/DC24V
OMRON Time interval table K3HB-PNB-A-DRT1 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Load sensor, mV instrument
K3HB-VLC-B-DRT1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-B-DRT1 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Rotating pulse meter
K3HB-RNB-A-DRT1 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-A-DRT1 AC/DC24V
Input type: NPN/ voltage pulse input type. E