OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3GN-PDT2-FLK DC24V datasheet PDF catalog K3GN-PDT2-FLK DC24V PDF datasheet

OMRON K3GN-PDT2-FLK DC24V datasheet PDF catalog K3GN-PDT2-FLK DC24V PDF datasheet

Brand: OMRON
Product model: K3GN-PDT2-FLK DC24V
Name: 1/32 DIN Digital Panel Meter
Sort: PDF datasheet
File language: English
File size: 1.48MB
Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs(SPST-NO);
Data transmission output, DC current (0 to 20 mA, 4 to 20 mA).
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) K3GN-PDT2-FLK DC24V PDF datasheet.
Multi-input compatible: DC voltage/current, rotary pulse K3GN-PDT2-FLK DC24V
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities K3GN-PDT2-FLK DC24V PDF datasheet.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters K3GN-PDT2-FLK DC24V PDF datasheet.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Type: KM50-C intelligent monitor.
Application circuit: single phase 2 wire system AC100 ~ 240V; single phase 3 wire system AC100/200V;
Three-phase 3 wire system AC100 ~ 240V.
Power supply voltage sharing: sharing AC100 to 240V with the measured voltage input.
Shape: 48 (H) * 48 (W) * 84 (D).
Communication: RS-485.
Protocol: ompoWay/F: the number of communication nodes 31 Modbus: the number of communication nodes 99 (shared).
Energy classification function (industry initiative).
Show the 3-STATE function through the 3 color display energy saving room for improvement.
Equipped with easy to grasp the room for energy saving and convenient 3-STATE function.
3-STATE function reffers to the use of the state power, the cumulative power is divided into operation / standby / stop 3 types of functions K3GN-PDT2-FLK DC24V datasheet PDF catalog.
2 and 3-STATE function linkage, can operate / standby / stop 3 points for individual output
(determine the object can be selected from power, current, voltage)
Pulse input count, pulse input ON time, unit power consumption measurement K3GN-PDT2-FLK DC24V datasheet PDF catalog.
Related products
OMRON
1/32 DIN Digital Panel Meter
K3GN-PDT2-FLK DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-PDT2-FLK DC24V
Supply voltage: 24 VDC. Input type: DC volta
OMRON
1/32 DIN Digital Panel Meter
K3GN-PDT2 DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-PDT2 DC24V
Supply voltage: 24 VDC. Input type: DC volta
OMRON
1/32 DIN Digital Panel Meter
K3GN-PDC-FLK DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-PDC-FLK DC24V
Supply voltage: 24 VDC. Input type: DC volta
OMRON
1/32 DIN Digital Panel Meter
K3GN-NLC-FLK DC24V
OMRON 1/32 DIN Digital Panel Meter K3GN-NLC-FLK DC24V
Supply voltage: 24 VDC. Input type: DC volta