Supply voltage: 12 VDC.
Control output: Contact output, SPDT (time-limit SPDT).
Eight-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch H7GP-TB PDF datasheet.
Sequence checks are easily performed by setting an instanta,
neous output to 0
H7GP-TB
Start signal control for the H3DK-M. Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: No H7GP-TB PDF datasheet.
Control output: Contact (SPST-NO).
Operating mode: Down counting.
Max.counting speed: 5 kcps (see note 1.).
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter H7GP-TB PDF datasheet.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Actuator: Roller lever.
Economical, Miniature Limit Switch.
Boasting Rigid Construction.
The Head, Box, and Cover mate with ridged surfaces to,
maintain strength.
A unique Head structure provides a large OT for smooth operation.
Easy-to-wire conduit opening design.
Ideal for application in printing machines, forming machines,
and light machines.
(High Switches with high sealing characteristics, such as WL or,
D4C Switches, in locations subject to oil, water, or precipitation.)
Models with grounding terminals conform to the CE marking.
Approved by CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A-2: Power ON Delay I, b: Repeat cyclle 1,
E: Interval, Z: ON/OFF-duty-adjustable flicker, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1 H7GP-TB datasheet PDF catalog.
External connections: 8-pin socket.
Input: None.
Output: Contact output (time-limit SPDT + instantaneous SPDT),
Models with instantaneous contact outputs H7GP-TB datasheet PDF catalog.
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.