Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common G9SX-NSA222-T03-RC PDF datasheet.
Output indicators: LED display (yellow) G9SX-NSA222-T03-RC
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max G9SX-NSA222-T03-RC PDF datasheet.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance G9SX-NSA222-T03-RC PDF datasheet.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance. Insulation method: Phototriac coupler.
Zero cross function: Yes.
Indicators: Yes(See page 5).
Rated output load: 20 A, 100 to 240 VAC (resistive load: AC, Class1).
Refer to Safety Precautions for All Solid State Relays.
Detects failures in SSR used for heater,
temperature control and simultaneously,
outputs alarm signal. This SSR supports the,
safe design of heater control systems, and,
contributes to maintenance improvements by the user.
Main detection items:
SSR short-circuuits and SSR open-circuits,
Alarm output possible to NPN/PNP-input devices G9SX-NSA222-T03-RC datasheet PDF catalog.
The failure-detection function is built-in and power is supplied,
from the main circuit power supply making wiring simple.
Slim design (width: 22 G9SX-NSA222-T03-RC datasheet PDF catalog. 5 mm) incorporating a heat sink.
In addition to screw mounting, DIN track mounting is also possible.
Certified by EC, UL, and CSA.