Type: output module.
Insulation: photo coupler.
Action indicator: there.
Zero trigger function: No.
Applicable load of output: DC48 1A ~ 200V.
Input rated voltage: DC24V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete G7J-3A1B-B PDF datasheet.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay
G7J-3A1B-B
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Classification: Output.
Internal I/O circuit common: PNP (– common).
Rated voltage: 24 VDC.
Reduces Wiring while Providing I/O G7J-3A1B-B PDF datasheet.
Flexibility.
Mount I/O relays and I/O SSRs freely.
Electric-shock preventive (finger-touch protection) terminal.
block incorporated conforming to VDE 0160.
Connects to the PC and SBC easily via a connector.
DIN track mounted.
I/O Block conforming to VDE 0160. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC G7J-3A1B-B PDF datasheet.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 15 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Cable /G79-Y_C with loose wire connecting terminal.
L size: 2000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Number of phase: Single-phase.
Control terminal block: Screwless clamp terminal block.
Type: Constant current.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 commmunications to set manipulated variables and,
monitor load current G7J-3A1B-B datasheet PDF catalog.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G7J-3A1B-B datasheet PDF catalog.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.