Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps G3RV-SR700-D AC230 PDF datasheet.
Detects the burnout of any one of a group of heaters
G3RV-SR700-D AC230
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable) G3RV-SR700-D AC230 PDF datasheet.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC 100V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G3RV-SR700-D AC230 PDF datasheet.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Main contacts: 3PST-NO.
OFF-delay contacts: DPST-NO.
Auxiliary contact: SPST-NC.
Number of input channels: 1 channel or 2 channels possible.
OFF-delay time: 7.5 s.
Rated voltage: 24 VAC/VDC; 100 to 240 VAC.
The G9SA Series Offers a Complete.
Line-up of Compact Units.
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, andd models with 3 poles,
and 2 OFF-delay poles, as well as a Two-hand Controller G3RV-SR700-D AC230 datasheet PDF catalog.
Also available are 17.5-mm wide Expansion Units with 3,
poles and 3 OFF-delay poles.
Simple expansion connection.
OFF-delayy models have 15-step OFF-delay settings G3RV-SR700-D AC230 datasheet PDF catalog.
Conforms to EN ISO13849-1 (PLe/Safety Category 4).
Both DIN track mounting and screw mounting are possible.