Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC *1.
Rated input voltage: 5 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”) G3PW-A260EC-C-FLK PDF datasheet.
Socket type, same size as LY Power Relays
G3PW-A260EC-C-FLK
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Cable with connector (1 to 3) /G79-_C-_-_.
L size: A, 1500mm; B, 1250mm; C, 1000mm.
Input use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable G3PW-A260EC-C-FLK PDF datasheet. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations G3PW-A260EC-C-FLK PDF datasheet.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contaccts for small load switching also available G3PW-A260EC-C-FLK datasheet PDF catalog.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed locatiion) G3PW-A260EC-C-FLK datasheet PDF catalog.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging.