Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC, 100V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel G2RV-SR700 DC12 PDF datasheet.
Realized opening and closing ability with one pole 6 A slim shape
G2RV-SR700 DC12
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs G2RV-SR700 DC12 PDF datasheet.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Isolation: Phototriac coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 5 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays G2RV-SR700 DC12 PDF datasheet.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Main contact: 3PST-NO.
Auxiliary contact: None.
Number of input channels: 2 channels.
Rated voltage: 24 VDC.
Less Wiring Required with Safety Light.
Curtain.
Sensor connector allows direct connection to OMRON F3SJ.
Safety Light Curtains with PNP outputs.
Reduces wiring and prevents incorrect connection.
Connection to emergency stop switch also supported.
Conforms to EN standards (TÜV approval).
DIN track mounting possible. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
ccapacity are provided in a compact body without the need of,
radiators G2RV-SR700 DC12 datasheet PDF catalog. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions G2RV-SR700 DC12 datasheet PDF catalog.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.