Safety instantaneous output: 2 (Semiconductor).
Safety slow-speed/stopping detection output: 2 (Semiconductor).
Auxiliary output: 4(Semiconductor).
Maximum set threshold: 10 Hz.
voltage Rated: 24 VDC.
Terminal block type: Spring-cage terminals.
Low-speed Monitoring Function Ensures.
Safety for Maintenance Work G2R-1-SD PDF datasheet.
Motor rotation speed detected by Proximity Sensor.
Monitors and confirms that speed does not exceed the preset level
G2R-1-SD
Includes an Enabling Switch input for maintenance work.
Detailed LED indications enable easy fault diagnosis.
Safety Category 3 (EN954-1), PLd(ISO13849-1),
SIL 3 (IEC/EN 62061) certified. Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC G2R-1-SD PDF datasheet.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 0.75 kW (2.4 A), 380 to 400 VAC.
Soft-start/stop Function Starts and Stops.
Three-phase Motors Smoothly and.
Economically.
Function like an inverter by holding down the starting current.
Comply with UL, CSA, IEC (400-V models only), and JEM.
requirements.
Mount with screws or to DIN tracks G2R-1-SD PDF datasheet.
Compact monoblock construction for the G3J-T217BL.
(W: 100 × H: 100 × D: 110 mm) with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator. Isolation: Photocoupler.
Zero cross function: --.
Indicator: NO.
Rated output load: 3 A at 4 to 48 VDC *2 .
Rated input voltage: 4 to 24 VDC.
New Models with International Standards.
Added to G3H Series (-VD in model number).
Same Profile as LY1 and LY2 Bi-power.
Relays.
Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
Socket type, same size as LY Power Relays.
Operation indicator provided to confirm input,
(models numbers with “N” before the suffix). Safety outputs: Instantaneous, --; OFF-delayed, 4 PST-NO.
Auxiliary outputs *1: 1(Semiconductor).
OFF-delay time: *2.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outpuuts (excluding Expansion Units) G2R-1-SD datasheet PDF catalog.
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unnit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set G2R-1-SD datasheet PDF catalog.
-Two logical AND connection inputs.