Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E6F-AB5C 360P/R 2M PDF datasheet.
Event input points: -
E6F-AB5C 360P/R 2M
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E6F-AB5C 360P/R 2M PDF datasheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E6F-AB5C 360P/R 2M PDF datasheet. , can be a key operation. Type: High-speed response models.
Connecting method: Wire-saving connector *1.
Model: PNP output.
Applicable wire-saving connector(sold separately):
Type,Master connector, Slave connector; Model, E3X-CN21, E3X-CN22.
Stable Detection with Advanced Fiber.
Amplifier Units.
A wide range of added value with standard models with one,
input and two outputs, and ultra-long-term APC models with an,
APC life of approximately 20 years.
Power turning to easily set the optimum light level.
Automatic Power Control (APC) is always enabled to stabilize,
emitter power with high accuracy.
GIGA RAY for stable detection with the highest level of power in,
this class even for low-reflective objects and large objects.
The E3X-DA0-S supports an EtherCAT Sensor Communications,
Unit or CompoNet Sensor Communications Unit.
Size: M18, Non-shielded.
Sensing distance: 16.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 61 (81).
Output configuration: NPN.
Operation modee NC E6F-AB5C 360P/R 2M datasheet PDF catalog.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpiecees are eliminated E6F-AB5C 360P/R 2M datasheet PDF catalog.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.