High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: there.
Shape: shield, M18.
Detection range: 7mm.
Action mode: NC. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V) E5AN-Q3HBTD-N PDF datasheet.
Shell color: black
E5AN-Q3HBTD-N
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: - E5AN-Q3HBTD-N PDF datasheet.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5AN-Q3HBTD-N PDF datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. E32-D33 type: special beam type; ultra small / small diameter beam,
Specialty: Phi 0.8 casing,
Bending radius (mm): R4.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsIn-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channnel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5AN-Q3HBTD-N datasheet PDF catalog.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E5AN-Q3HBTD-N datasheet PDF catalog.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.