OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON E2A-S08LS02-M5-B1 datasheet PDF catalog E2A-S08LS02-M5-B1 PDF datasheet

OMRON E2A-S08LS02-M5-B1 datasheet PDF catalog E2A-S08LS02-M5-B1 PDF datasheet

Brand: OMRON
Product model: E2A-S08LS02-M5-B1
Name: Cylindrical Proximity Sensor
Sort: PDF datasheet
File language: English
File size: 0.54MB
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater E2A-S08LS02-M5-B1 PDF datasheet.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E2A-S08LS02-M5-B1
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E2A-S08LS02-M5-B1 PDF datasheet.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2A-S08LS02-M5-B1 PDF datasheet.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermmostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2A-S08LS02-M5-B1 datasheet PDF catalog.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E2A-S08LS02-M5-B1 datasheet PDF catalog.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Cylindrical Proximity Sensor
E2A-S08LN04-M1-B1
OMRON Cylindrical Proximity Sensor E2A-S08LN04-M1-B1
Size: M8, Non-shielded. Sensing distance: 4.
OMRON
Cylindrical Proximity Sensor
E2A-S08LS02-WP-C2 2M
OMRON Cylindrical Proximity Sensor E2A-S08LS02-WP-C2 2M
Size: M8, Shielded. Sensing distance: 2.0 mm
OMRON
Cylindrical Proximity Sensor
E2A-S08LN04-WP-C1 2M
OMRON Cylindrical Proximity Sensor E2A-S08LN04-WP-C1 2M
Size: M8, Non-shielded. Sensing distance: 4.
OMRON
Cylindrical Proximity Sensor
E2A-S08LN04-M5-B1
OMRON Cylindrical Proximity Sensor E2A-S08LN04-M5-B1
Size: M8, Non-shielded. Sensing distance: 4.