OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON D4SL-N3HFA-DN datasheet PDF catalog D4SL-N3HFA-DN PDF datasheet

OMRON D4SL-N3HFA-DN datasheet PDF catalog D4SL-N3HFA-DN PDF datasheet

Brand: OMRON
Product model: D4SL-N3HFA-DN
Name: Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
Sort: PDF datasheet
File language: English
File size: 6.12MB
Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4SL-N3HFA-DN PDF datasheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4SL-N3HFA-DN
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4SL-N3HFA-DN PDF datasheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type: Welding / wire type, M3 screw mounting.
Driving rod: R type swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1c D4SL-N3HFA-DN PDF datasheet.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Release key type: Trapped key *1.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor conttacts provide an,
array of monitoring patterns D4SL-N3HFA-DN datasheet PDF catalog.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4SL-N3HFA-DN datasheet PDF catalog.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.