OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON D4E-2C10N datasheet PDF catalog D4E-2C10N PDF datasheet

OMRON D4E-2C10N datasheet PDF catalog D4E-2C10N PDF datasheet

Brand: OMRON
Product model: D4E-2C10N
Name: Small closed limit switch
Sort: PDF datasheet
File language: English
File size: 1.70MB
Type: Welding / wire type, M3 screw mounting.
Drive rod: needle shaped button type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4E-2C10N PDF datasheet.
No swing bars are also used for easy long stroke specifications (OT reference value: 1 D4E-2C10N4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Side plunger, Horizontal roller.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength D4E-2C10N PDF datasheet.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations D4E-2C10N PDF datasheet.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable roller lever.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped wwith a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4E-2C10N datasheet PDF catalog.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4E-2C10N datasheet PDF catalog.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Related products
OMRON
Small closed limit switch
D4E-1H20N
OMRON Small closed limit switch D4E-1H20N
Type: screw terminal type, general type witho
OMRON
Small closed limit switch
D4E-1B10N
OMRON Small closed limit switch D4E-1B10N
One touch type: connector type, general type.
OMRON
Small closed limit switch
D4E-2H20N
OMRON Small closed limit switch D4E-2H20N
Type: screw terminal type, small load without
OMRON
Small closed limit switch
D4E-2F10N
OMRON Small closed limit switch D4E-2F10N
Type: one touch type connector, small load.