Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement D4C-2550 PDF datasheet.
Standardized gold-clad contacts provide high contact reliability
D4C-2550
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger (Metal roller).
Cable length: 1 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 4NC (slow-action) D4C-2550 PDF datasheet.
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC D4C-2550 PDF datasheet. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitorr contacts provide an,
array of monitoring patterns D4C-2550 datasheet PDF catalog.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4C-2550 datasheet PDF catalog.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.