Actuator: Plunger.
Conduit openings: M20.
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D4BL-2GRD-AT PDF datasheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
D4BL-2GRD-AT
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) D4BL-2GRD-AT PDF datasheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4BL-2GRD-AT PDF datasheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
withhout detaching the head D4BL-2GRD-AT datasheet PDF catalog.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4BL-2GRD-AT datasheet PDF catalog.
The plastic material makes the Slide Key suitable,
for lightweight doors.