Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface,Open-loop control by,
pulse train output/Line-driver output;
Number of control axes, 1 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: U, C, N, L, CE CS1W-PDC01 PDF datasheet.
High-speed, High-precision,
positioning with 1, 2, or 4 axes
CS1W-PDC01
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control.Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units CS1W-PDC01 PDF datasheet.
Specifications:12 to 24 VDC,
0.5A 32 outputs; Sinking.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 words.
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: UC1, N, L, CE CS1W-PDC01 PDF datasheet.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
2 RS-232C ports;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.28A; 24V,--.
Standarrds: UC1, N, L, CE CS1W-PDC01 datasheet PDF catalog.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CS1W-PDC01 datasheet PDF catalog.