C500-OD I/O Unit Transistor Output 16 pts C500-OD215(3G2A5-OD215).
DC24V 50mA.Name: External Connector.
Model: C500-CE405.
Specifications: Crimp-style terminal; 40p and a Connector Cover (Horizontal-
type).C500-NC Special I/O Unit C/CV Servo Module Single Axis Stepper C500-NC111-V1.Product name: N@@-type CPU Units with 30 I/O Points CRT1B-OD04JS PDF datasheet.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Transistor (sinking)
CRT1B-OD04JS
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CRT1B-OD04JS PDF datasheet.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: C200HW-COM02-V1.
Specifications: One RS-232C port.CV500-RM SYSMAC BUS Remote I/O Master Unit (optical) CV500-RM211.
Light type.I/O Interface UnitProduct name: N@@-type CPU Units with 60 I/O Points CRT1B-OD04JS PDF datasheet.
Specifications: Power Supply, 24 VDC; Inputs, 36; Outputs, 24;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. NO. OF I/O SLOTS: 11 SLOTSName: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CRT1B-OD04JS datasheet PDF catalog.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRT1B-OD04JS datasheet PDF catalog.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.