1 set (2 included).For 5-slot Backplane.I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
ABS interface: Yes.CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP223-E.
4-MB memory; w/floating-point processor.Short protection for 10-pin terminal block (package of 10 covers) CJ1W-PA205R PDF datasheet. 8 pts.One Ethernet Option Board can be mounted in either option board slot 1 or 2
CJ1W-PA205R
Note: Cannot be used for the CP1L-L10.CPU Unit: CP1H-Y CPU Units.
Specifications: CPU type, Memory capacity: 20K steps,
High-speed counters: 1 MHz, 2 axes 100 kHz, 2 axes Pulse,
outputs: 1 MHz, 2 axes 100 kHz, 2 axes;
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 12+line-driver input, 2 axes; Output, 8+ine-driver output, 2 axes CJ1W-PA205R PDF datasheet.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O. Name: Controller Link Module.
Model: C200HW-CLK21.
Communications method: N: N token bus CJ1W-PA205R PDF datasheet.
Code Manchester: codeModel : CV500-CN228.
BASIC for connecting the unit ← → FIT10 (2m).Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 8 outputs;
Maximum switching capacity, 24VDC,
0.5A Short-circuit protection;
Commons, 8 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.10A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CJ1W-PA205R datasheet PDF catalog.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ1W-PA205R datasheet PDF catalog.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.