OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON GT1-DA04MX Manual GT1-DA04MX Safety Precautions

OMRON GT1-DA04MX Manual GT1-DA04MX Safety Precautions

Brand: OMRON
Product model: GT1-DA04MX
Name: TEMPERATURE INPUT UNIT
Sort: Safety Precautions
File language: English
File size: 0.24MB
Isolation: Phototriac.
Zero cross function: No.
Indicator: No.
Rated output load: 5 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model GT1-DA04MX Safety Precautions.
Dedicated, compact aluminum PCB and power elements used GT1-DA04MX
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1 GT1-DA04MX Safety Precautions. ).
Rated input voltage: 12 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix) GT1-DA04MX Safety Precautions. Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 35 A, 200 to 480 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Main contact: 3PST-NO.
Auxiliary contact: None.
Number of input channels: 2 channels GT1-DA04MX Manual.
Rated voltage: 24 VDC.
Less Wiring Required with Safety Light.
Curtain.
Sensor connector allows direct connection to OMRON F3SJ.
Safety Light Curtains with PNP outputs.
Reduces wiring and preveents incorrect connection GT1-DA04MX Manual.
Connection to emergency stop switch also supported.
Conforms to EN standards (TÜV approval).
DIN track mounting possible.