Slim and Space-saving Power Plug-in Relay.
Reduces wiring work by 60% when combined with the,
P2RF-@-PU Push-In Plus Socket.
(according to actual OMRON measurements).
Lockable test button models available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic,
function (LED type) G9SA-321-T075 user's manual.
High switching power (1-pole: 10 A)
G9SA-321-T075 Name: Safety Controller.
Number of I/O: Safety inputs, 10; Test outputs, 4;
Safety outputs, Solid-state outputs: 4; Standard outputs, 4.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application G9SA-321-T075 user's manual.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, verification, standardization and reusage of,
safety control by unique programming software G9SA-321-T075 user's manual.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified. Type: Microload.
Latching lever (Test switch): No.
Rated input voltage: DC, 21.
Applicable model: G2RV-SR700/500-AP DC24V, G2RV-SR700/500-AP AC/DC24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters G9SA-321-T075 Manual.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G9SA-321-T075 Manual.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.