Number of beams: 13.
Protective height: 620mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions F3SJ-A1805P20-01TS INSTRUCTION sheet. Number of beams: 25.
Protective height: 620mm.
Model: PNP output
F3SJ-A1805P20-01TS
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Product name: Liquid Leakage Point Sensor.
Main material: Polyethylene.
Cable material: Outer sheath: PVC Inner sheath: Fluoroplastic F3SJ-A1805P20-01TS INSTRUCTION sheet.
Electrode material: SUS304 and fluoroplastic coating.
A New Liquid Leakage Point Sensor Has Been Added,
to the K7L Series. Fluoroplastic Coating on the,
Bottom Electrode Ensures Chemical Resistance.
Can be used in conjunction with Sensing Bands.
Stud screw mounting requires no tools for installation.
No tools means the Sensor can be wiped clean quickly and easily F3SJ-A1805P20-01TS INSTRUCTION sheet.
The optional Mounting Bracket enables faster installation than three-screw,
mounting.
Connect multiple Sensors to one K7L Amplifier for significant cost savings. Number of beams: 32.
Protective height: 795mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Number of beams: 50.
Protective height: 461mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Material: Titanium.
Weight (g): Approx. 100.
Material indication lines: 5 lines.
A Wide Variety of Electrodes for Long Lasting.
Reliability.
Standard Electrodes are made of stainless steel (SUS 304) and,
can be ussed in applications for purified water F3SJ-A1805P20-01TS Manual.
SUS316 Electrodes can be used in applications where resistance,
to corrosion is required. Titanium and HAS Electrodes can be,
used in applications where resistance to acid is requuired F3SJ-A1805P20-01TS Manual.
For applications where long electrodes are required, a connection,
nut and two Lock Nuts can be used to extend the electrodes 1 m,
at a time.