Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, No; Mounting option units, No.
Previous model: E5AZ-R3 E5AZ-A3 + E53-AZR.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better ES2-M INSTRUCTION Manual.
Controllers now available with analog inputs
ES2-M
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications ES2-M INSTRUCTION Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Appearance: Unshielded, M12.
Sensing distance: 4 mm.
Output configuration: DC 3-wire, PNP.
Model: Operation mode, NC.
General-purpose Threaded.
Capacitive Sensor.
Product lineup with M12, M18, and M30 models.
Fixed sensing distance requires no sensitivity adjustment. Appearance: M12 ES2-M INSTRUCTION Manual.
Sensing distance: 8 mm.
Connection method: M12 Connector Models .
Cable specifications: --.
Polarity: Yes.
Operation mode : NC.
Pin arrangement: 1: +V, 2: 0 V.
Applicable connector code: D.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to chheck the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV ES2-M Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output ES2-M Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.