Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: - E5ER-QT3DB-FLK INSTRUCTION Manual.
Communication: RS-485.
Event input: 1 points
E5ER-QT3DB-FLK
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms E5ER-QT3DB-FLK INSTRUCTION Manual.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately) E5ER-QT3DB-FLK INSTRUCTION Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: M8 connector (3-pin).
Body material: Stainless steel.
Thread length (overall length): 27 (39).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5ER-QT3DB-FLK Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault