OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5EN-HSS2HH02BF-FLK Communications Functions MANUAL E5EN-HSS2HH02BF-FLK User's Manual

OMRON E5EN-HSS2HH02BF-FLK Communications Functions MANUAL E5EN-HSS2HH02BF-FLK User's Manual

Brand: OMRON
Product model: E5EN-HSS2HH02BF-FLK
Name: Temperature Controller
Sort: User's Manual (Communications Functions)
File language: English
File size: 0.55MB
Classification: Exclusive Models.
Description: Corrosionresistant model.
Temperature range (See note 3.): 0°C to 180°C.
Element type: K (CA).
Conductor type: Nongrounded type.
Class: 2 (0.75).
Protective tubing material: Fluororesin tubing.
Terminal type: Exposed lead wires.
Page: 24.
A Wide Variety of High-precision E5EN-HSS2HH02BF-FLK User's Manual.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-HSS2HH02BF-FLK
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EN-HSS2HH02BF-FLK User's Manual. Size: 96 × 96 mm.
Control type: Control valve control(1 loop).
Control mode: Single-loop position-proportional control.
Outputs(control/transfer): Relay outputs(1 open, 1 closed)and 1 current.
Optional functions: Auxiliary outputs (SUB), 10 (See note 1.);
Event inputs, 8; Serial communications, RS-485 .
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total E5EN-HSS2HH02BF-FLK User's Manual.
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application. Size: 48 x 48mm.
Body: terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event input points: -.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5EN-HSS2HH02BF-FLK Communications Functions MANUAL.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
Related products