OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5EN-C1T Communications Functions MANUAL E5EN-C1T User's Manual

OMRON E5EN-C1T Communications Functions MANUAL E5EN-C1T User's Manual

Brand: OMRON
Product model: E5EN-C1T
Name: Temperature Controller
Sort: User's Manual (Communications Functions)
File language: English
File size: 0.55MB
Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5EN-C1T User's Manual.
Event input points: - E5EN-C1T
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5EN-C1T User's Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5EN-C1T User's Manual. , can be a key operation. Control output 1: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLCC with programless communications E5EN-C1T Communications Functions MANUAL.
Use component communications to link Temperature.
Controllers to each other. Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Pre-wirred E5EN-C1T Communications Functions MANUAL.
Sensing distance: 700 mm.
Functions: Timer Self Diagnosis .
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors.
Related products
OMRON
Foundation type temperature controller
E5EN-Q3H03T-W-FLK-N
OMRON Foundation type temperature controller E5EN-Q3H03T-W-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-Q3H03T-FLK-N
OMRON Foundation type temperature controller E5EN-Q3H03T-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Programmed temperature controller
E5EN-HTPRR2BBFD
OMRON Programmed temperature controller E5EN-HTPRR2BBFD
Size: 48 x 96mm. Type: power AC/DC24V with. S
OMRON
Programmed temperature controller
E5EN-HTPRR203BF-FLK
OMRON Programmed temperature controller E5EN-HTPRR203BF-FLK
Size: 48 x 96mm. Category: power AC100 240V