Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5EC-TPR4ASM-082 INSTRUCTION Manual.
Event input points: -.
Transfer output: -
E5EC-TPR4ASM-082
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EC-TPR4ASM-082 INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Classification: Exclusive Models.
Description: Corrosionresistant model.
Temperature range (See note 3.): 0°C to 180°C.
Element type: K (CA).
Conductor type: Nongrounded type E5EC-TPR4ASM-082 INSTRUCTION Manual.
Class: 2 (0.75).
Protective tubing material: Fluororesin tubing.
Terminal type: Exposed lead wires.
Page: 24.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Relay output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%)),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs E5EC-TPR4ASM-082 Manual.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E5EC-TPR4ASM-082 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.