Element type: R (See note 2.).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EC-QQ4ASM-009 INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers
E5EC-QQ4ASM-009
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector E5EC-QQ4ASM-009 INSTRUCTION Manual.
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Size: 96 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications E5EC-QQ4ASM-009 INSTRUCTION Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Size: 1/8 DIN 48 × 96 × 78(W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Voltage output(for driving SSR).
Functions: Heater burnout, No; Mounting option units, Yes.
Previous model: E5EZ-Q3 + E53-AZM .
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms E5EC-QQ4ASM-009 Manual.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protoocol called Modbus is installed in the,
models with communications E5EC-QQ4ASM-009 Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.