Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater E5EC-QQ2ASM-009 INSTRUCTION Manual.
Event entry point: 2
E5EC-QQ2ASM-009
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E5EC-QQ2ASM-009 INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EC-QQ2ASM-009 INSTRUCTION Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Sensing method: Reflective type.
Sensing distance: 0 to 3 mm.
Output configuration: Turns ON when wafer carrier is present.
Cable length: 2 m.
Photomicrosensors for detecting,
wafer-carrier mounting.
The mounting position is set with a pedestal.
The contact surface with the wafer carrier uses a special chemical,
resistant fluororesin.
The unique optical system enables stable detection of almost all,
wafer-carriers.
Light modulation effectively reduces external light interference.
Utilizes talc-free clean cables. Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 1 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications E5EC-QQ2ASM-009 Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E5EC-QQ2ASM-009 Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.