OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CS-QGU-W Manual E5CS-QGU-W INSTRUCTION Manual

OMRON E5CS-QGU-W Manual E5CS-QGU-W INSTRUCTION Manual

Brand: OMRON
Product model: E5CS-QGU-W
Name: temperature controller
Sort: INSTRUCTION Manual
File language: English
File size: 14.72MB
Pressure range: 0 to 5.00 kPa.
Digital output: NPN open collector.
Linear output: 4 to 20 mA.
Micropressure Sensor with.
Easy-to-Read Digital Display.
Repeat accuracy of ±1% FS (setting resolution: 0.01 kPa),
high-precision pressure control available.
Compact design (31 × 30 × 30 mm) saves mounting space E5CS-QGU-W INSTRUCTION Manual.
Easy-to-read red LED indicator.
Analog current output models available (E8Y-A@Y) E5CS-QGU-W
Pressure port Rc (PT) 1/8 models available (-R).
EN and UL approved. High performance price ratio standard type proximity sensor.Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling E5CS-QGU-W INSTRUCTION Manual.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5CS-QGU-W INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thhe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CS-QGU-W Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CS-QGU-W Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products