OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTQ2BFD Manual E5CN-HTQ2BFD INSTRUCTION Manual

OMRON E5CN-HTQ2BFD Manual E5CN-HTQ2BFD INSTRUCTION Manual

Brand: OMRON
Product model: E5CN-HTQ2BFD
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 1.32MB
Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5CN-HTQ2BFD INSTRUCTION Manual.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5CN-HTQ2BFD Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5CN-HTQ2BFD INSTRUCTION Manual.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors E5CN-HTQ2BFD INSTRUCTION Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Sensing method: Through-beam (Emitter + Receiver).
Connection method: Pre-wired M8 connector.
Sensing distance: 15m.
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light.
Size: Shielded, M18.
Sensing disttance: 5 mm E5CN-HTQ2BFD Manual.
Output: DC 2-Wire (polarity).
Operation mode: NO.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) ffittings E5CN-HTQ2BFD Manual.
Chemical resistance certified by Ecolab Europe.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating.
Related products
OMRON
Programmed temperature controller
E5CN-HTQ2H03D-FLK
OMRON Programmed temperature controller E5CN-HTQ2H03D-FLK
Size: 48 48mm, terminal type. Type: control
OMRON
High performance temperature controller
E5CN-HC201-W-FLK
OMRON High performance temperature controller E5CN-HC201-W-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
Programmed temperature controller
E5CN-HTQQ201-FLK
OMRON Programmed temperature controller E5CN-HTQQ201-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
High performance temperature controller
E5CN-HQ2H01-FLK
OMRON High performance temperature controller E5CN-HQ2H01-FLK
Size: 48 x 48mm. Body: terminal type. Categor