Appearance: M8.
Sensing distance: 2 mm.
Connection method: M8 Connector Models.
Cable specifications: --.
Operation mode : NO .
Pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Applicable connector code: I.
Model: PNP output.
Your Search for Proximity Sensors.
Starts with the World-leading E5CN-HR2M-W-500 INSTRUCTION Manual.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals
E5CN-HR2M-W-500
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection E5CN-HR2M-W-500 INSTRUCTION Manual.
Cable protector provided as a standard feature. Easy and optimum settings for anyone.
Smart Fiber Amplifier Unit with Long-term Stable Detection.
Equipped with Smart Tuning, which automatically configures the,
settings to their optimum values with the press of a single button.
Highly usable design enables anyone to configure the settings easily.
Detects dirt, vibrations, and LED deterioration, and automatically,
compensates the incident level and the light intensity E5CN-HR2M-W-500 INSTRUCTION Manual.
Unparalleled best-in-class power provides stable detections for low,
reflective workpieces and large workpieces (equipped with GIGA RAY II). Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (special terminal).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5CN-HR2M-W-500 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5CN-HR2M-W-500 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.