E32-S15L-2 optical fiber unit using OMRON''s unique polarized multilayer film technology (FAO)
Can not be affected by the color of the workpiece, the subtle luster
To carry out a stable testTerminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 20 cm E5CC-QQ2DSM-003 INSTRUCTION Manual.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision
E5CC-QQ2DSM-003
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CC-QQ2DSM-003 INSTRUCTION Manual. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5CC-QQ2DSM-003 INSTRUCTION Manual.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Power supply voltage: DC.
Sensing method: Through-beam (Emitter + Receiver).
Sensing distance: 5 m.
Output configu ration: PNP.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2 E5CC-QQ2DSM-003 Manual. 5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectaable power supply input (24 to 240 VDC, 24 to 240 VAC) E5CC-QQ2DSM-003 Manual.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available.