OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CC-CX3DSM-005 Manual E5CC-CX3DSM-005 INSTRUCTION Manual

OMRON E5CC-CX3DSM-005 Manual E5CC-CX3DSM-005 INSTRUCTION Manual

Brand: OMRON
Product model: E5CC-CX3DSM-005
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 0.65MB
Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: -- E5CC-CX3DSM-005 INSTRUCTION Manual.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5CC-CX3DSM-005
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E5CC-CX3DSM-005 INSTRUCTION Manual. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E5CC-CX3DSM-005 INSTRUCTION Manual.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia. . .
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output 1: Linear current output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operattion E5CC-CX3DSM-005 Manual.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E5CC-CX3DSM-005 Manual.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.
Related products
OMRON
Digital Temperature Controller
E5CC-CX2ASM-800
OMRON Digital Temperature Controller E5CC-CX2ASM-800
Control output 1: Linear current output. Aux
OMRON
Digital temperature controller
E5CC-RX3DSM-005
OMRON Digital temperature controller E5CC-RX3DSM-005
Size: 48 x 48mm. Control output 1: relay out
OMRON
Digital temperature controller
E5CC-CX2ASM-007
OMRON Digital temperature controller E5CC-CX2ASM-007
Size: 48 x 48mm. Control output 1: linear cu
OMRON
Digital temperature controller
E5CC-QX2DSM-005
OMRON Digital temperature controller E5CC-QX2DSM-005
Size: 48 x 48mm. Control output 1: voltage o