Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 96 x 96mm.
Ontology: terminal type, temperature input type E5AC-CX4ASM-004 INSTRUCTION Manual.
Category: control output 1 point type (power supply AC100 ~ 240V)
E5AC-CX4ASM-004
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: - E5AC-CX4ASM-004 INSTRUCTION Manual.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5AC-CX4ASM-004 INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: -.
Event input: -.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remotee SP input, suitable for a wide range of applications E5AC-CX4ASM-004 Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5AC-CX4ASM-004 Manual.
A new type of proportional control allows you to control the valve.