OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E4PA-LS200-M1-N Manual E4PA-LS200-M1-N INSTRUCTION sheet

OMRON E4PA-LS200-M1-N Manual E4PA-LS200-M1-N INSTRUCTION sheet

Brand: OMRON
Product model: E4PA-LS200-M1-N
Name: ultrasonic sensor
Sort: INSTRUCTION sheet
File language: English
File size: 0.89MB
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E4PA-LS200-M1-N INSTRUCTION sheet.
Event input points: - E4PA-LS200-M1-N
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E4PA-LS200-M1-N INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: relay.
Input: Platinum resistance E4PA-LS200-M1-N INSTRUCTION sheet.
New generation intelligent general temperature controller.
The thickness is only 78 mm.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed. Size: 48 * 48mm, terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E4PA-LS200-M1-N Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E4PA-LS200-M1-N Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Ultrasonic Displacement Sensor
E4PA-LS400-M1-N
OMRON Ultrasonic Displacement Sensor E4PA-LS400-M1-N
Sensing range: 240 to 4,000 mm. Now, more ad
OMRON
Ultrasonic Displacement Sensor
E4PA-LS200-M1-N
OMRON Ultrasonic Displacement Sensor E4PA-LS200-M1-N
Sensing range: 120 to 2,000 mm. Now, more ad
OMRON
Ultrasonic Displacement Sensor
E4PA-LS600-M1-N
OMRON Ultrasonic Displacement Sensor E4PA-LS600-M1-N
Sensing range: 400 to 6,000 mm. Now, more ad
OMRON
Ultrasonic Displacement Sensor
E4PA-LS50-M1-N
OMRON Ultrasonic Displacement Sensor E4PA-LS50-M1-N
Sensing range: 50 to 500 mm. Now, more advan