OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E3ZM-T68 Manual E3ZM-T68 INSTRUCTION sheet

OMRON E3ZM-T68 Manual E3ZM-T68 INSTRUCTION sheet

Brand: OMRON
Product model: E3ZM-T68
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 22.48MB
E3JK-R92J regression reflection type,
E3JK communication type: mode; shading ON,
Miniature amplifier built-in type photoelectric switchSize: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general) E3ZM-T68 INSTRUCTION sheet.
Power supply voltage: AC100 ~ 240V E3ZM-T68
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use E3ZM-T68 INSTRUCTION sheet.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply E3ZM-T68 INSTRUCTION sheet.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The coonnection method can be selected from a screw terminal and a PUSH-IN fastening terminal E3ZM-T68 Manual.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E3ZM-T68 Manual.
It can be easily set by CS-Thermo (sold separately).
Related products
OMRON
Compact Photoelectric Sensor
E3ZM-D87
OMRON Compact Photoelectric Sensor  E3ZM-D87
Sensing method: Diffuse reflective. Connecti
OMRON
Compact Photoelectric Sensor
E3ZM-LS89H
OMRON Compact Photoelectric Sensor  E3ZM-LS89H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-LS82H
OMRON Compact Photoelectric Sensor  E3ZM-LS82H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-T61
OMRON Compact Photoelectric Sensor  E3ZM-T61
Sensing method: Through eam Emitter Recei