Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3Z-LT61-M1J INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers
E3Z-LT61-M1J
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: M12, Non-shielded.
Sensing distance: 8.0 mm.
Connection: M12 connector.
Body material: Brass E3Z-LT61-M1J INSTRUCTION sheet.
Thread length (overall length): 56 (70).
Output configuration: PNP.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels) E3Z-LT61-M1J INSTRUCTION sheet.
Modular construction simplifies customization. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of tthe thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E3Z-LT61-M1J Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E3Z-LT61-M1J Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.