Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3Z-G82-M1J INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers
E3Z-G82-M1J
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Appearance: T-shaped, slot center 10 mm.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles) E3Z-G82-M1J INSTRUCTION sheet.
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON.
Complete lineup including seven different shapes E3Z-G82-M1J INSTRUCTION sheet.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations.
Connector with lock that mates with commercially available,
connectors. Name: Reflectors.
Directional angle: 30° min.
Ambient operating temperature range: -25 to 55°C.
Ambient storage temperature range: -40 to 70°C.
Ambient operating humidity range: 35% to 85%.
Ambient storage humidity range: 35% to 95%.
Degree of protection: IEC IP67.
Accessories: --. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mmanual, RUN/STOP, alarm), interactive display PV/SV E3Z-G82-M1J Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E3Z-G82-M1J Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.