OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E3T-FL14-M1TJ Manual E3T-FL14-M1TJ INSTRUCTION sheet

OMRON E3T-FL14-M1TJ Manual E3T-FL14-M1TJ INSTRUCTION sheet

Brand: OMRON
Product model: E3T-FL14-M1TJ
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.70MB
Software for setting parameters.
A software can correspond to a variety of models
Can use the computer to compile, edit, transfer all parameters.
Reducing the time when setting the same parameters to multiple devices,
Can monitor the content of the set, the current value.
The parameters of the system can be output in the form of CSV and HTML E3T-FL14-M1TJ INSTRUCTION sheet. Ontology: basic.
Size: 48 x 96mm E3T-FL14-M1TJ
Type: basic type (1 input)
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 point (pulse voltage + pulse voltage / current).
Output (SUB) points: 2 points.
Event entry point: 6.
Serial communication: RS-485.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line E3T-FL14-M1TJ INSTRUCTION sheet.
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation.
1 digital controller can be multi point control / series control / proportion control.
Standard is equipped with a variety of computing functions E3T-FL14-M1TJ INSTRUCTION sheet.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3T-FL14-M1TJ Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E3T-FL14-M1TJ Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.