Brand: OMRON
Product model: E3T-FD14
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.70MB
Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E3T-FD14 INSTRUCTION sheet.
Event entry point: 4 E3T-FD14
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E3T-FD14 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E3T-FD14 INSTRUCTION sheet. , can be a key operation. Sensing method: Through-beam type.
Sensing distance: 1m.
Output type: NPN output.
Output configuration: Dark-ON.
Through-beam Photomicrosensor.
with a sensing distance as long as 1 m.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Light modulation effectively reduces external light interference.
Easy-to-wire connector assures ease of maintenance. Size: 48 x 96mm.
Control output 1: double relay (proportional valve).
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms E3T-FD14 Manual.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion E3T-FD14 Manual.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.
Related products
OMRON
Photoelectric Sensors
E3T-FT21
OMRON Photoelectric Sensors E3T-FT21
Sensing method: Through-eam Emitter Recei
OMRON
Photoelectric Sensors
E3T-SL12
OMRON Photoelectric Sensors E3T-SL12
Sensing method: Convergent-reflective. Conne
OMRON
Photoelectric Sensors
E3T-ST12
OMRON Photoelectric Sensors E3T-ST12
Sensing method: Through-eam. Connection met