Sensing method: Through-beam type (with slot).
Sensing distance: 3.6 mm (slot width).
Output type: NPN output.
Output configuration: Dark-ON.
Photomicrosensor with light,
modulation for reduced external,
light interference and a,
connector for easy maintenance.
Built-in connectors.
Select from four easy-to-use shapes for efficient space,
utilization E3S-AT11-D-M1J INSTRUCTION sheet.
Connectors with locks for safety against vibration
E3S-AT11-D-M1J
Convenient mounting method using M3 screws.
Wide operating voltage range: 5 to 24 VDC. Appearance: 6.5 dia.
Sensing distance: 2 mm.
Connecting method: M8 Connector Models.
Cable specifications: --.
Operation mode: NC.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output E3S-AT11-D-M1J INSTRUCTION sheet.
Model: PNP output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation E3S-AT11-D-M1J INSTRUCTION sheet.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables.
Sensing method: Through-beam (Emitter + Receiver).
Connection method: Standard M8 connector.
Sensing distance: 15 m.
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog(current/voltage).
Alarm output: 2.
option units Mounting: Yes.
Control output: Voltage output(for driving SSR).
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models avaiilable with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E3S-AT11-D-M1J Manual.
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protoocol called Modbus is installed in the models,
with communications E3S-AT11-D-M1J Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.