OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E2V-X8B2 Manual E2V-X8B2 INSTRUCTION sheet

OMRON E2V-X8B2 Manual E2V-X8B2 INSTRUCTION sheet

Brand: OMRON
Product model: E2V-X8B2
Name: proximity sensor
Sort: INSTRUCTION sheet
File language: English
File size: 4.11MB
Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - E2V-X8B2 INSTRUCTION sheet.
Event input points: -.
Transfer output: output (using control output) E2V-X8B2
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E2V-X8B2 INSTRUCTION sheet.
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultThe main body: terminal type, temperature input type E2V-X8B2 INSTRUCTION sheet.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E2V-X8B2 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E2V-X8B2 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
All Metals and Long-distance Types
E2V-X8B1-M1TJ 0.3M
OMRON All Metals and Long-distance Types E2V-X8B1-M1TJ 0.3M
Appearance: Shielded, M18. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X8B1-M1
OMRON All Metals and Long-distance Types E2V-X8B1-M1
Appearance: Shielded, M18. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X15B1-M1
OMRON All Metals and Long-distance Types E2V-X15B1-M1
Appearance: Shielded, M30. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X4B1 2M
OMRON All Metals and Long-distance Types E2V-X4B1 2M
Appearance: Shielded, M12. Sensing distance: