OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E2V-X5C2 Manual E2V-X5C2 INSTRUCTION sheet

OMRON E2V-X5C2 Manual E2V-X5C2 INSTRUCTION sheet

Brand: OMRON
Product model: E2V-X5C2
Name: proximity sensor
Sort: INSTRUCTION sheet
File language: English
File size: 4.11MB
Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: - E2V-X5C2 INSTRUCTION sheet.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E2V-X5C2
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors E2V-X5C2 INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E2V-X5C2 INSTRUCTION sheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. E3F3-D81M detection method: diffuse reflection type,
Wire lead out type,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: 48 x 48mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: there.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variiety of applications E2V-X5C2 Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E2V-X5C2 Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Related products
OMRON
All Metals and Long-distance Types
E2V-X4B1-M1
OMRON All Metals and Long-distance Types E2V-X4B1-M1
Appearance: Shielded, M12. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X2B2 2M
OMRON All Metals and Long-distance Types E2V-X2B2 2M
Appearance: Shielded, M12. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X15C1-M1TJ 0.3M
OMRON All Metals and Long-distance Types E2V-X15C1-M1TJ 0.3M
Appearance: Shielded, M30. Sensing distance:
OMRON
All Metals and Long-distance Types
E2V-X8B1-M1
OMRON All Metals and Long-distance Types E2V-X8B1-M1
Appearance: Shielded, M18. Sensing distance: