E32-D14L type: standard type; standard,
Specialty: 6 cylinder side,
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsTerminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 35 cm E2S-Q12 INSTRUCTION sheet.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision E2S-Q12
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2S-Q12 INSTRUCTION sheet. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 50cm.
Lead wire type: Heat resistive.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2S-Q12 INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automaticc / manual, RUN/STOP, alarm), interactive display PV/SV E2S-Q12 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2S-Q12 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Super-compact Proximity Sensor
E2S-W24 1M
OMRON Super-compact Proximity Sensor E2S-W24 1M
Appearance: Unshielded. Sensing surface: Top
OMRON
Super-compact Proximity Sensor
E2S-W12 1M
OMRON Super-compact Proximity Sensor E2S-W12 1M
Appearance: Unshielded. Sensing surface: Top